This post covers 9 concepts from the Pharmaceutical Analysis chapter of the RRB Pharmacist syllabus. Each concept has the key points, a worked example, a memory trick and an exam tip. Points tagged with a year were asked in that RRB paper.
Choosing the Titration Indicator
Match indicator range to equivalence pH.
- Weak acid with strong base: equivalence above 7. Use phenolphthalein (8.3 to 10).
- Strong acid with strong base: pH 7. Any indicator works.
- Strong acid with weak base: below 7. Use methyl orange or methyl red.
- Weak with weak: no sharp end point. Use potentiometry.
- The deciding factor is the indicator's colour-change pH range.
ExampleAcetic acid titrated with NaOH ends near pH 8.7, inside phenolphthalein's range.
Memory trickWeak acid, Pink end point
Exam tipUniversal indicator is green at pH 7.
Indicator Colour Table
Range and colour change in one table.
- Methyl orange: pH 3.1 to 4.4, red to yellow.
- Methyl red: 4.4 to 6.2, red to yellow.
- Bromothymol blue: 6.0 to 7.6, yellow to blue.
- Phenolphthalein: 8.3 to 10.0, colourless to pink.
- Litmus: 4.5 to 8.3, red to blue.
- Equivalent weight of H2SO4 = 98 / 2 = 49.
ExampleA solution that turns pink with phenolphthalein has pH above about 8.3.
Memory trickMethyl Orange = Acid zone
Exam tipMetal-ion indicators (Eriochrome Black T, murexide) are for EDTA titrations.
Electrochemical Methods
What each method measures.
- Potentiometry measures EMF at zero current.
- Conductometry measures conductance.
- Amperometry measures current at fixed potential, for electroreducible substances.
- Redox end point: indicator, potentiometric or amperometric.
- Inert electrodes (platinum, graphite) only carry electrons.
- Nernst equation relates cell voltage to concentration.
ExampleA glass electrode used in a pH meter is a potentiometric sensor.
Memory trickPotentio = Potential, Ampero = Current
Exam tipKarl Fischer end point uses amperometry.
Spectroscopy Basics
Which energy change each technique senses.
- Spectrophotometry measures absorbed radiation. Flame photometry measures emitted radiation.
- UV-Vis: electronic transitions, 200 to 800 nm.
- IR: vibrational changes, 4000 to 400 per cm.
- NMR: nuclear spin flips in a magnetic field.
- Beer-Lambert: A = epsilon x c x l.
- Atomic absorption: ground-state atoms for trace metals.
ExampleFlame photometry estimates sodium and potassium in a sample.
Memory trickIR = Vibration, UV = Electron
Exam tipMass spectrometry gives molecular weight.
UV Shifts
Four words for how a peak moves.
- Bathochromic (red) shift: lambda max moves to a longer wavelength.
- Hypsochromic (blue) shift: moves to a shorter wavelength.
- Hyperchromic: absorbance increases.
- Hypochromic: absorbance decreases.
- Auxochromes (OH, NH2), polar solvents and more conjugation cause red shift.
ExampleAdding an NH2 auxochrome to a chromophore raises absorbance and shifts the peak red.
Memory trickBatho = Big wavelength, Hypso = Short
Exam tipAsked in RRB 2019.
Chromatography Techniques
Principle and detector for each.
- GC: gas mobile phase. Flame ionisation detector is the commonest.
- HPLC: high-pressure liquid. Pulse damper smooths the pump flow. Detectors UV, RI, fluorescence.
- Affinity chromatography uses specific biological binding like antigen-antibody.
- TLC: Rf = solute distance / solvent distance.
- Ion exchange separates by charge. Gel filtration separates by size.
- HPLC reversed phase uses C18.
ExampleRf can never be more than 1 because the solute cannot outrun the solvent front.
Memory trickGC = FID
Exam tipAffinity chromatography principle was asked in RRB 2025.
Kjeldahl, Thermal and Limit Tests
Method facts that repeat.
- Kjeldahl digests nitrogen with conc. H2SO4 plus K2SO4 and CuSO4 catalyst into ammonium sulphate.
- DTA records temperature difference between sample and an inert reference.
- Limit test for iron uses thioglycolic acid to reduce Fe3+.
- TGA tracks mass loss. DSC tracks heat flow.
- Serum creatinine is a more reliable indicator of kidney function.
ExampleProtein content of milk is found from nitrogen estimated by Kjeldahl.
Memory trickKjeldahl = Nitrogen
Exam tipDTA compares to an inert reference.
Method Validation Parameters
ICH-style terms with one-line meanings.
- Accuracy: closeness to true value.
- Precision: reproducibility of results.
- Linearity: response proportional to concentration.
- Range: interval where method is accurate, precise and linear.
- LOD and LOQ: smallest detectable and quantifiable amounts.
- Specificity: unambiguous assessment of the analyte.
- Robustness: unaffected by small deliberate changes.
ExampleThree weighings give 5.01, 5.02, 5.01 g for a true value of 6 g. Precise but not accurate.
Memory trickAccuracy = Aim, Precision = Same place
Exam tipRounding 7.045 to two places keyed as 7.04 in RRB 2025.
Titration Types and Indicators
Which titrant, which indicator.
- Mohr (argentometric): silver nitrate with chloride, K2CrO4 indicator.
- Volhard: back titration with KSCN, ferric alum indicator.
- Iodometry: sodium thiosulphate, starch blue to colourless.
- Permanganometry: KMnO4 is its own indicator, pink end point.
- Complexometry: EDTA with Eriochrome Black T, wine red to blue at pH 10.
- Non-aqueous: perchloric acid in glacial acetic acid, crystal violet.
- Diazotisation: sodium nitrite plus HCl, starch-iodide paper outside.
ExampleWater hardness is measured by EDTA titration using Eriochrome Black T.
Memory trickKMnO4 = Self indicator
Exam tipKarl Fischer reagent measures water content.
Practise this chapter
Attempt timed questions on Pharmaceutical Analysis and check your answers with explanations at Pharma Insights Academy.
Join RRB Pharmacist courseOpen test series